Energy Meter
The Energy Meter is a Deye accessory — for monitoring, metering, communication or module-level control — used in Deye installations. It comes in 5 versions.
Add it to a quotation for an inverter or battery system, or ask for it on its own.
No prices online: every order is quoted in writing.
- Manufacturer's category
- Accessory & Monitoring
- Models on this page
- 5
Models
| Model |
|---|
| CHNTDDSU666 |
| CHNTDTSU666 |
| EASTRON SDM 230 Modbus |
| EASTRON SDM 630-Modbus V2 |
| EASTRONSDM630MCTV2 |
Technical specifications
Values as published by the manufacturer, one column per model where the manufacturer's table has them.
A value across all model columns is the same for every model.
| Model | CHNTDDSU666 | CHNTDTSU666 | EASTRON SDM 230 Modbus | EASTRON SDM 630-Modbus V2 | EASTRONSDM630MCTV2 |
|---|---|---|---|---|---|
| Max. direct current measurement (A) | 60 | 80 | 100 | 100 | 1-9999A (with CT) |
| Direct Voltage measurement between phases | — | 176-458V | — | 147-480V | 50-950V |
| Direct Voltage measurement between phases | — | 176-458V | — | 147-480V | 50-550V |
| Direct measurement between phase and neutral | 176~264V | 100-265V | 176~276V | 85~480V | 20-550V |
| Model | CHNTDDSU666 | CHNTDTSU666 | EASTRON SDM 230 Modbus | EASTRON SDM 630-Modbus V2 | EASTRONSDM630MCTV2 |
|---|---|---|---|---|---|
| Active power | Class1 | ||||
| Reactive power | Class2 | ||||
| Model | CHNTDDSU666 | CHNTDTSU666 | EASTRON SDM 230 Modbus | EASTRON SDM 630-Modbus V2 | EASTRONSDM630MCTV2 |
|---|---|---|---|---|---|
| Power consumption | ≤1W / 8VA | ≤1.5W / 6VA | ≤2W / 10VA | ≤2W / 10VA | ≤2W / 10VA |
| AC power supply input voltage | 176-264V | 100-265V | 176-276V | 85-480V | 85-275V / 120-380V |
| AC power supply input frequency | 50/60Hz | 50/60Hz | 50Hz | 50/60Hz ±2% | 50/60Hz ±2% |
| Model | CHNTDDSU666 | CHNTDTSU666 | EASTRON SDM 230 Modbus | EASTRON SDM 630-Modbus V2 | EASTRONSDM630MCTV2 |
|---|---|---|---|---|---|
| Dimenstions (L/H/W) in mm | 36×85×66 | 100×72×66 | 36×99×63 | 72×100×66 | 72×94.5×65 |
| Weight (kg) | 0.21 | 0.44 | 0.21 | 0.42 | 0.29 |
| Mounting options | DIN Rail | ||||
| Degree of protection | IP51 | ||||
| Display | LCD | ||||
| Communication interface | RS485 | ||||
| Max. number of devices to connect | 32 | ||||
| Regulated working temperature range | -25℃~+55℃ | -10℃~+45℃ | -25 ℃~+55 ℃ | -25 ℃~+55 ℃ | -25 ℃~+55 ℃ |
| Limited working temperature range | -40℃~+70℃ | 25℃~+75℃ | — | — | — |
| Humidity | ≤75% | ≤75% | 0~95%, non-Condensing | 0~95%, non-Condensing | 0~95%, non-Condensing |
| Warranty | 1.5 years | ||||
Documents
- DatasheetDatasheet · EN · PDF ↗
- User manualManual · 1.4 MB · PDF ↗
All documents open from the manufacturer's own servers, so you always get the file Deye currently publishes. Most are in English.
Key features
As listed by the manufacturer.
- Local LCD display, RS485 communication
- Adopting the standard DIN35mm din rail mounting
- Small volume, easy installation and easy communication
- Positive and reverse active power, four quadrant reactive power metering
Independent dealerSECURISTIKA SRL is an independent dealer of Deye products. This website is not affiliated with, endorsed by or operated by the manufacturer.
Specifications, features and documents as published by the manufacturer. Check the current datasheet before you order. Source page (opens in a new tab)
Related series
Monitoring
Deye Cloud

Monitoring
Data Logger

Energy management
Smart Transmitter (TX)

Module-level
MECD
Tell us what you are building
Send the models and quantities, or just the system size and the site country. We reply with a written quotation.